Table 3 The results of subjective image quality analysis

From: Acceleration of knee magnetic resonance imaging using a combination of compressed sensing and commercially available deep learning reconstruction: a preliminary study

 

ACL

MCL

MM

LM

Bone

Noise

Artifact

Overall

Reader 1

 1NSA-DLR

4.14 ± 0.35

4.90 ± 0.29

4.95 ± 0.21

5.00 ± 0.00

4.00 ± 0.00

3.71 ± 0.45

4.81 ± 0.39

3.76 ± 0.43

 4NSA

3.76 ± 0.43

4.23 ± 0.68

3.95 ± 0.79

4.29 ± 0.88

3.86 ± 0.35

3.05 ± 0.21

4.42 ± 1.14

3.00 ± 0.69

 p value

0.03

0.001

< 0.001

0.005

0.15

< 0.001

0.14

0.003

Reader 2

 1NSA-DLR

4.19 ± 0.39

4.52 ± 0.50

4.48 ± 0.50

4.48 ± 0.50

4.00 ± 0.00

3.95 ± 0.21

5.00 ± 0.00

3.95 ± 0.37

 4NSA

3.71 ± 0.63

3.81 ± 0.59

3.86 ± 0.77

3.95 ± 0.72

3.81 ± 0.39

3.05 ± 0.37

4.52 ± 1.17

2.90 ± 0.61

 p value

0.02

0.001

0.008

0.02

0.07

< 0.001

0.17

< 0.001

Reader 3

 1NSA-DLR

4.19 ± 0.39

4.62 ± 0.49

4.57 ± 0.49

4.52 ± 0.50

4.05 ± 0.21

3.95 ± 0.21

4.86 ± 0.35

3.95 ± 0.21

 4NSA

3.90 ± 0.53

4.14 ± 0.77

3.86 ± 0.94

4.00 ± 0.82

3.90 ± 0.43

3.43 ± 0.58

4.43 ± 1.00

3.29 ± 0.76

 p value

0.04

0.03

0.01

0.02

0.23

0.001

0.10

< 0.001

  1. All variables are expressed as the mean ± standard deviation. p values that indicate significant differences are shown in bold