Skip to main content

Table 2 The results of objective image quality analysis

From: Acceleration of knee magnetic resonance imaging using a combination of compressed sensing and commercially available deep learning reconstruction: a preliminary study

 

Meniscus

Cartilage

Diff(Cart – Meni)

CNR

p value

Mean

SD

Mean

SD

Mean

Lateral side

 1NSA-DLR

869.7

267.1

3029.3

797.0

2159.6

2.61 ± 0.51

< 0.001

 4NSA

721.0

382.5

2857.7

921.7

2136.7

2.18 ± 0.58

 

Medial side

 1NSA-DLR

1030.8

380.1

3440.6

1032.7

2409.7

2.19 ± 0.32

< 0.001

 4NSA

864.6

484.7

3248.8

1124.8

2384.2

1.97 ± 0.36

 
  1. For meniscus and cartilage, mean and SD of the signal intensity of each structure is described. Diff(Cart – Meni) represents the difference in signal intensity of cartilage and meniscus. SDs are expressed as their mean and CNRs are expressed as the mean ± standard deviation. p values are shown for the comparison of CNR and the p values that indicate significant differences are shown in bold