Skip to main content

Table 1 The accuracy, sensitivity, specificity, and Youden's Index of DCEUS and MDCT for assessing gross classification of gastric cancer

From: Double contrast-enhanced ultrasound for the preoperative gross classification of gastric cancer: a comparison with multidetector computed tomography

 

Accuracy, % (n)

Sensitivity, % (n)

Specificity, % (n)

Youden's index

DCEUS

EGC

96% (52/54)

75% (6/8)

100% (46/46)

0.75

Borrmann I

96% (52/54)

100% (2/2)

96% (50/52)

0.96

Borrmann II

87% (47/54)

17% (1/6)

96% (46/48)

0.13

Borrmann III

72% (39/54)

90% (27/30)

50% (12/24)

0.40

Borrmann IV

89% (48/54)

25% (2/8)

100% (46/46)

0.25

Borrmann III + IV

83% (45/54)

92% (35/38)

63% (10/16)

0.55

MDCT

EGC

92% (50/54)

62% (5/8)

98% (45/46)

0.60

Borrmann I

94% (51/54)

50% (1/2)

96% (50/52)

0.46

Borrmann II

80% (43/54)

33% (2/6)

85% (41/48)

0.18

Borrmann III

74% (40/54)

73% (22/30)

75% (18/24)

0.48

Borrmann IV

96% (52/54)

88% (7/8)

98% (45/46)

0.86

Borrmann III + IV

78% (42/54)

82% (31/38)

69% (11/16)

0.51

  1. DCEUS, double contrast-enhanced ultrasound; EGC, early gastric cancer; MDCT, multidetector computed tomography