Skip to main content

Table 1 Mean operative differences in T2 landmark distance (mm) between operators. Paired t-test results for the accuracy between hand and automated superimposition, both compared with true values in cranial base superimposition

From: The application and accuracy of feature matching on automated cephalometric superimposition

 

N

Operative difference

(Hand process) (mm)

N

Accuracy (Hand process)

(mm)

Accuracy (Automated process)

(mm)

P-value

Mean

SD

Mean

SD

Mean

SD

Pt

84a

0.61

0.63

28

0.33

0.28

0.41

0.37

0.128

PNS

84

0.69

0.65

28

0.40

0.32

0.47

0.39

0.290

ANS

84

0.82

0.76

28

0.47

0.38

0.54

0.45

0.313

A

84

0.85

0.86

28

0.50

0.42

0.59

0.54

0.274

B

84

0.99

0.94

28

0.58

0.46

0.59

0.48

0.880

Me

84

1.02

0.96

28

0.55

0.51

0.64

0.58

0.366

Go

84

0.91

0.88

28

0.52

0.43

0.48

0.50

0.626

Co

84

0.67

0.68

28

0.39

0.34

0.44

0.35

0.254

  1. aBecause three operators were compared, a total 28 pairs of cephalograms could yield 84 measurement values