Skip to main content

Table 6 Intra-observer agreement of 5D Heart in obtaining 8 diagnostic planes

From: Novel foetal echocardiographic image processing software (5D Heart) improves the display of key diagnostic elements in foetal echocardiography

Diagnostic Planes

kappa-value

95%CI

3VT

0.770

0.627–0.913

Four chamber

1.000

0.987–1.000

LVOT

0.655

0.485–0.826

RVOT

0.656

0.517–0.795

Abdomen/stomach

1.000

0.987–1.000

Ductal arch

0.755

0.663–0.847

Aortic arch

0.615

0.517–0.713

SVC/RA/IVC

0.689

0.568–0.811

  1. 3VT three-vessels and trachea view; LVOT: left ventricular outflow tract view, RVOT right ventricular outflow tract view, SVC/RA/IVC superior and inferior vena cava/ right atrium, CI confidence interval