Skip to main content

Table 4 Analysis of incremental value of each block in the automatic Segment MaR CE-SSFP algorithm (n = 183)

From: Automatic segmentation of myocardium at risk from contrast enhanced SSFP CMR: validation against expert readers and SPECT

 

MaR bias [% of LVM]

Regression

DSC

R-value

Intensity classification by EM

2 ± 8

0.60

0.65 ± 0.18

+ intensity correctiona

2 ± 8

0.63

0.74 ± 0.12

+ a priori on MaR

-4 ± 10

0.62

0.81 ± 0.16

+ infarct region from LGE

1 ± 6

0.83

0.85 ± 0.08

  1. EM Expectation Maximization, MaR Myocardium at risk, LGE late gadolinium enhancement, LVM Left ventricular mass, DSC Dice similarity coefficient, aapplied in 127/183 patients