Skip to main content

Table 2 Inter- and intra-observer reliability (intra class correlation- ICC) for femoral, tibial and combined femoral-tibial component position after UKA

From: A novel standardized algorithm using SPECT/CT evaluating unhappy patients after unicondylar knee arthroplasty– a combined analysis of tracer uptake distribution and component position

   

Intraobserver-reliability

Interobserver-reliability

Measurement

Mean

SD

U1

U2

U1-U2

Femoral component

  Varus-valgus

2.3

3.8

0.80

0,92

0.92

  Flexion-extension

15.3

6.5

0.92

0.91

0.91

  Internal rotation- external rotation

−4.3

5.0

0.74

0.92

0.92

Tibial component

  Varus-valgus

7.0

3.6

0.94

0.95

0.95

  Flexion-extension

−6.3

5.0

0.98

0.99

1.00

  Internal rotation- external rotation

−4.7

3.5

0.87

0.91

0.91

Combined femoral and tibial component

  Internal rotation- external rotation

10.2

7.1

0.93

0.95

0.95

Tibiofemoral angle

  Tibiofemoral angle

−1.7

2.8

0.98

0.99

0.98