Table 3 ROI backscattered light intensity (dB) and maximum penetration depth of optical signal (mm) under the surface of OCT image

From: A pilot and ex-vivo study of examination of endometrium tissue by catheter based optical coherence tomography

 

Proliferative endometrium

Secretory Phase endometrium

Atrophic endometrium

Endometrial hyperplasia with atypia

Endometrial carcinoma

F

p value

ROI minimum intensity (dB)

37.23 ± 12.69

30.93 ± 8.20

31.02 ± 7.33

33.17 ± 7.59

115.87 ± 25.95

77.589

p < 0.001

ROI maximum intensity (dB)

79.67 ± 14.70

109.81 ± 4.02

76.40 ± 5.77

84.42 ± 4.01

187.05 ± 14.16

209.474

p < 0.001

ROI average intensity (dB)

62.90 ± 14.09

89.73 ± 5.85

65.23 ± 8.36

58.25 ± 6.95

155.62 ± 16.68

104.161

p < 0.001

OCT signal maximum penetration depth (mm)

2.54 ± 0.27

2.26 ± 0.12

2.71 ± 0.12

2.44 ± 0.21

1.62 ± 0.26

44.001

p < 0.001

  1. p < 0.05 means that the statistical difference was significant