Skip to main content

Table 1 Magnetic resonance imaging sequence parameters

From: Reproducibility and feasibility of optic nerve diffusion MRI techniques: single-shot echo-planar imaging (EPI), readout-segmented EPI, and reduced field-of-view diffusion-weighted imaging

 

T2w imaging

rs-EPI DWI

rFOV DWI

ss-EPI DWI

TR (ms)

4400

4650

3500

3700

TE (ms)

99

68

65

80

FOV (mm2)

180 × 180

180 × 108

120 × 98

210 × 210

Voxel size (mm2)

0.5 × 0.5 × 2.5

1.1 × 1.1 × 2.5

1.3 × 1.3 × 2.5

1.8 × 1.8 × 2.5

b-value (s/mm2)

–

0, 1000

0, 1000

0, 1000

Diffusion directions

–

3

3

3

Averages per b-value

–

2,2

2,10

2,10

PAT mode

GRAPPA

GRAPPA

GRAPPA

GRAPPA

Acceleration factor PE

2

2

2

2

In-plane resolution (mm2)

0.5 × 0.5

1.1 × 1.1

1.3 × 1.3

1.8 × 1.8

Slice thickness (mm)

2.5

2.5

2.5

2.5

Base resolution

384

160

96

120

Echo spacing (mm)

11.0

0.36

0.99

0.76

Bandwidth (Hz/px)

250

679

1158

1488

EPI factor

–

96

78

120

B0 Shim mode

Standard

Standard

Standard

Standard

TA (min)

1:47

3:12

2:03

2:11

  1. rs-EPI DWI, readout-segmented echo-planar imaging diffusion-weighted imaging; rFOV, reduced field-of-view; ss-EPI, single-shot echo-planar imaging; TE, echo time; TR, repetition time, TA, acquisition time, GRAPPA: generalized autocalibrating partially parallel acquisitions