Skip to main content

Table 2 Performance metrics for Models A and B

From: Automated detection of pulmonary embolism from CT-angiograms using deep learning

Metric

Model A

Model B

Stacks

Slices

Stacks

Slices

Accuracy

90.2 (85.1–93.8)

92.3 (91.9–92.7)

87.3 (81.7–91.4)

90.1 (89.6–90.5)

Sensitivity

86.6 (77.8–92.4)

90.1 (89.0–91.2)

83.5 (74.3–90.0)

90.8 (89.7–91.9)

Specificity

93.5 (86.5–97.1)

92.7 (92.2–93.1)

90.7 (83.1–95.2)

89.9 (89.4–90.4)

PPV

92.3 (84.3–96.6)

69.9 (68.3–71.4)

89.0 (80.3–94.3)

62.3 (61.2–64.2)

NPV

88.5 (80.8–93.5)

98.1 (97.8–98.3)

85.8 (77.8–91.4)

98.1 (97.9–98.3)

  1. Results are in percentage (%) with 95% CI