Skip to main content

Table 1 MRI sequences and parameters

From: Prediction of overall survival in patients with pancreatic ductal adenocarcinoma: histogram analysis of ADC value and correlation with pathological intratumoral necrosis

Parameter

Intera Achieva Quasar Dual

Ingenia 3.0T CX

T1WI

In/out

T2WI

DWI

T1WI

In/out

T2WI

DWI

Sequence

3D TFE

GRE

2D TSE

2D EP

3D TFE

GRE

2D TSE MV

2D EP

Respiratory control

BH

BH

RT

FB

BH

BH

RT

FB

Fat suppression

Yes

No

Yes

Yes

Yes

No

Yes

Yes

TR (ms)

3.3

242

1900

5000

3.3

223

2000

5000

TE (ms)

1.57

1.2/2.4/3.6/4.8

80

63

1.56

1.15/2.35/3.55/4.75

80

63

Flip angle (°)

15

60

90

90

12

60

90

90

FOV (cm)

42 × 30

38 × 30

38 × 30

38 × 30

42 × 30

38 × 30

38 × 38

38 × 30

Matrix

320 × 224

288 × 230

512 × 256

128 × 128

304 × 250

288 × 230

304 × 304

128 × 128

Parallel imaging factor

1.5

2.2

2

2

1.7

2

2.5

2

Slice thickness (mm)

4

5

5

6

4

5

5

6

Intersection gap (mm)

− 2

1

1

0

− 2

1

1

0

No. of sections

90

30

30

30

90

30

30

30

Acquisition time

20 s

21 s

3 min

1 min 45 s

20 s

17 s

3 min

1 min 45 s

b values (mm2/s)

NA

NA

NA

0, 200, 800

NA

NA

NA

0, 200, 800

  1. T1WI, T1-weighted imaging; T2WI, T2-weighted imaging; DWI, diffusion-weighted imaging; 3D, three dimensional; 2D, two dimensional; FFE, fast field-echo; GRE, gradient recalled-echo; TSE, turbo spin-echo; EP, echo-planar; MV, Multi Vane; BH, breath-hold; RT, respiratory-triggered; FB, free-breathing; TR, repetition time; TE, echo time; FOV, field of view; NA, not applicable