From: Development and validation of the 3D U-Net algorithm for segmentation of pelvic lymph nodes on diffusion-weighted images
Suspicious LNs
Largest LNs
True positive
226
41
False Positive
5
0
False Negative
4
Precision
0.97
1.00
Recall
0.98
F1-score