Skip to main content

Table 7 Correlation and agreement of LVCO and AAO forward flow volume between 4D flow and 2D sequences

From: Right and left ventricular function and flow quantification in pediatric patients with repaired tetralogy of Fallot using four-dimensional flow magnetic resonance imaging

  Correlation LOA Mean difference
4D LVCO vs. 4D AAO forward flow volume 0.924 (− 1.52, 0.47) − 0.52 ± 0.51
2D LVCO vs. 2D AAO forward flow volume 0.944 (− 1.21, 0.54) − 0.34 ± 0.45
4D RVCO vs. 4D MPA forward flow volume 0.834 (− 2.20, 3.33) 0.57 ± 1.41
2D RVCO vs. 2D MPA forward flow volume 0.967 (− 1.01, 1.56) 0.27 ± 0.66