Skip to main content

Table 2 Correlation analysis between the iodine level and thyroid function index (Spearman)

From: Iodine concentration and content measured by dual-source computed tomography are correlated to thyroid hormone levels in euthyroid patients: a cross-sectional study in China

  

FT3

TT3

FT4

TT4

TSH

Sex

Age

CT value

Total iodine content

R Value

0.500*

0.180

−0.088

0.194

−0.368*

− 0.432*

− 0.249

0.361*

p Value

0.001

0.253

0.577

0.218

0.015

0.004

0.108

0.017

Iodine concentration

R Value

0.433*

0.337*

−0.132

0.122

−0.147

− 0.068

− 0.278

0.531*

p Value

0.004

0.029

0.398

0.443

0.346

0.667

0.071

0.000

Age

R Value

−0.394*

−0.131

−0.008

0.224

0.227

0.117

1.000

−0.318*

p Value

0.009

0.407

0.961

0.119

0.143

0.457

0.000

0.037

Volume

R Value

0.253

−0.107

−0.093

0.135

−0.273

− 0.590*

0.003

− 0.083

p Value

0.102

0.502

0.555

0.393

0.076

0.000

0.987

0.599

CT value

R Value

0.342*

0.000

−0.040

0.066

−0.209

− 0.173

−0.318*

1.000

p Value

0.025

1.000

0.800

0.677

0.178

0.268

0.037

0.000

Sample size

N

43

42

43

42

43

43

43

43

  1. *p < 0.05