Table 1 MRI acquisition parameters

From: Reduced regional flow in the left ventricle after anterior acute myocardial infarction: a case control study using 4D flow MRI

Parameter2D Short-Axis bSSFP4D flow (PC VIPR)2D LGE Scar Imaging
ECG typeprospectively gatedretrospectively gatedtriggered (diastolic phase)
Cine Frames2020
Respiratory Motion Strategybreath holdingfree-breathingbreath holding
Repetition Time (ms)3.1–4.15.8–8.44.0–4.8
Echo Time (ms)1.1–1.22.0–2.51.4–2.2
Flip Angle (degrees)458–1220–45
Inversion Time (μs)183–400
Field of View (cm2)39 × 3935 × 35
Slice Thickness (mm)88
Imaging Volume (cm3)32 × 32 × 20
Acquired Spatial Resolution (mm)1.74 × 1.741.25 × 1.25 × 1.252.03 × 2.03
Reconstructed Spatial Resolution (mm)1.25 × 1.25High resolution reconstruction:1.25 × 1.25 × 1.25
Low resolution reconstruction:
2.5 × 2.5 × 2.5
1.37 × 1.37
Velocity Encoding (cm/s)100–150
  1. Note—Reported values are the ranges (minima and maxima) for each parameter. Parameters were tailored to each individual’s anatomy and the field strength used. Two sets of images were reconstructed for each 4D flow acquisition: a high-resolution image set used to compute flow and ventricular KE, and a low-resolution image set used to separate LV flow components by tracking pathlines