Table 2 Description of MRI parameters for Philips Achieva 1.5 T SE MRI systems

From: Apparent diffusion coefficient as an effective index for the therapeutic efficiency of brain chemoradiotherapy for brain metastases from lung cancer

 

T1WI

T2WI

FLAIR

DWI

Contrast-enhanced*

TR (ms)

488

4748

8000

3090

156

TE (ms)

15

110

120

102

2.4

TI (ms)

2200

Slice thickness (mm)

6

6

6

6

6

Slice gap (mm)

1

1

1

1

1

Slice number of scanning (layers)

18

18

18

18

20

Scanning time (s)

24

42

24

36

22

NSA

1

2

2

1

2

Field of view (mm2)

230 × 201

230 × 201

230 × 183

230 × 201

230 × 199

Matrix

256 × 256

256 × 256

256 × 512

152 × 256

388 × 640

  1. *The Contrast-enhanced scan was performed by rapid bolus injection of gadopentate glucosamine (Gd-DTPA) at a dose of 0.1 mmol/kg through the cubital vein at a flow rate of 2.5 ml/s. After bolus injection, 20 mL of saline was intravenously injected. B-values for DWI are 0 s/mm2 and 1000 s/mm2