Skip to main content

Table 5 Evaluation of registration result (lung)

From: The same modality medical image registration with large deformation and clinical application based on adaptive diffeomorphic multi-resolution demons

Experiment Method

MSE/(A.U.)

NCC/(A.U.)

Structural Similarity/(A.U.)

our method

1371.9

0.9685

0.7911

diffeomorphic demons

1427.4

0.9678

0.7847

additive demons

1409.3

0.9385

0.7088

active demons

1401.8

0.9377

0.7043

standard result

1002.1

0.9874

0.8210