Skip to main content

Table 3 Significant differences between the image types

From: Usefulness of grayscale inverted images in addition to standard images in digital mammography

Parameter

Image type

No (%)

Yes (%)

Cochran’s Q

p

Multiple comparison

Macro-calcification

(a) Standard

234 (73.58)

84 (26.42)

8.375

0.015*

(c)

(b) Grayscale inverted

232 (72.96)

86 (27.04)

 

(c) Std + Gsi

225 (70.75)

93 (29.25)

(a)

Micro-calcification

(a) Standard

287 (90.25)

31 (9.75)

68.509

<0.001¶

(b) (c)

(b) Grayscale inverted

265 (83.33)

53 (16.67)

(a) (c)

(c) Std + Gsi

237 (74.53)

81 (25.47)

(a) (b)

Intramammary Lymph Nodes

(a) Standard

269 (84.59)

49 (15.41)

6.461

0.039†

(c)

(b) Grayscale inverted

261 (82.08)

57 (17.92)

 

(c) Std + Gsi

259 (81.45)

59 (18.55)

(a)

  1. Std + Gsi standard plus grayscale inverted image. *: a versus c. ¶: a versus b, a versus c, and b versus c. †: a versus c