Table 2 Population based end systolic displacement results. Manual and automatic measurement results of atrioventricular plane displacement (AVPD) in end systole as mean ± SD in the left (LVAVPD) and right ventricle (RVAVPD) for patients (n = 65), healthy controls (n = 24), and athletes (n = 24). Comparison of automatic tracking vs manual measurements as correlation R value and bias ± SD of the AVPD

From: Time-resolved tracking of the atrioventricular plane displacement in Cardiovascular Magnetic Resonance (CMR) images

Measure Manual Automatic R Bias ± SD
LVAVPD in patients [mm] −11 ± 2 −11 ± 2 0.81 −0.6 ± 1.3
RVAVPD in patients [mm] −17 ± 4 −15 ± 3 0.83 −1.0 ± 2.2
LVAVPD in healthy controls [mm] −14 ± 3 −14 ± 2 0.49 0.0 ± 2.5
RVAVPD in healthy controls [mm] −20 ± 4 −20 ± 3 0.88 −0.4 ± 1.7
LVAVPD in athletes [mm] −16 ± 2 −15 ± 2 0.44 −1.3 ± 2.3
RVAVPD in athletes [mm] −22 ± 3 −21 ± 2 0.77 −0.7 ± 2.2