Skip to main content

Table 2 Objective image noise measurements

From: Image quality improvement using model-based iterative reconstruction in low dose chest CT for children with necrotizing pneumonia

Tissue

Imagea

CT value

Noise

SNR

Mean ± SD

P

Mean ± SD

P

Mean ± SD

P

Consolidated lesion

MBIR

71.1 ± 9.3

-

13.9 ± 4.0

-

5.5 ± 1.6

-

ASIR

67.9 ± 12.7

0.13

24.9 ± 6.6

<0.01

2.9 ± 0.9

<0.01

5 mm FBP

63.9 ± 7.9

<0.01

17.2 ± 6.4

0.02

4.1 ± 1.3

<0.01

FBP

68.9 ± 12.1

0.10

33.8 ± 8.7

<0.01

2.2 ± 0.6

<0.01

Necrotic area

MBIR

14.8 ± 5.7

-

9.4 ± 1.4

-

1.6 ± 0.6

-

ASIR

16.2 ± 5.5

0.02

22.3 ± 1.6

<0.01

0.7 ± 0.3

<0.01

5 mm FBP

15.6 ± 5.0

0.19

9.9 ± 1.8

0.25

1.6 ± 0.6

0.92

FBP

16.2 ± 5.0

0.05

30.2 ± 3.0

<0.01

0.5 ± 0.2

<0.01

Muscle

MBIR

57.4 ± 7.2

-

12.1 ± 2.2

-

4.9 ± 1.1

-

ASIR

56.3 ± 6.6

0.48

22.7 ± 4.3

<0.01

2.6 ± 0.7

<0.01

5 mm FBP

56.6 ± 6.6

0.49

12.9 ± 2.3

0.07

4.5 ± 0.8

0.04

FBP

56.2 ± 8.9

0.21

30.7 ± 5.8

<0.01

1.9 ± 0.5

<0.01

Air

MBIR

−994.8 ± 4.3

-

3.6 ± 1.9

-

−407.9 ± 280.0

-

ASIR

−996.7 ± 3.2

0.08

11.2 ± 2.1

<0.01

−92.3 ± 18.8

0.01

5 mm FBP

−996.8 ± 2.6

0.09

5.2 ± 1.2

<0.01

−203.9 ± 51.4

0.02

FBP

−996.5 ± 4.0

0.16

15.0 ± 2.7

<0.01

−69.0 ± 14.5

0.01

  1. aImages were 0.625 mm in thickness unless stated otherwise