Fig. 4

From: Automatic segmentation of myocardium at risk from contrast enhanced SSFP CMR: validation against expert readers and SPECT

Fig. 4

Correlation and bias against SPECT for automatic segmentation and manual delineation in CE-SSFP. Correlation of MaR as % of LVM (left column) and Bland-Altman plot of MaR bias as % of LVM (right column) against SPECT for automatic segmentation algorithm Segment MaR CE-SSFP (top row) and manual reference delineation (bottom row). The line of identity is shown as a solid line for all correlations plots and mean bias (solid line) and mean ± two standard deviations (dashed line) is shown for all Bland-Altman plots. Correlation and Bland-Altman plots for manual delineation in CE-SSFP against SPECT (bottom row) are adopted from Sorenson et al. [4]