From: Automated lesion detection on MRI scans using combined unsupervised and supervised methods
α | λ | Accuracy | Precision | Recall | Dice |
---|---|---|---|---|---|
0.2 | 1 | 0.953±0.012 | 0.321±0.195 | 0.784±0.165 | 0.430±0.166 |
3 | 0.959±0.012 | 0.392±0.198 | 0.726±0.164 | 0.478±0.168 | |
5 | 0.961±0.011 | 0.427±0.199 | 0.694±0.156 | 0.497±0.165 | |
7 | 0.963±0.011 | 0.446±0.199 | 0.673±0.158 | 0.508±0.164 | |
0.4 | 1 | 0.965±0.011 | 0.502±0.199 | 0.639±0.154 | 0.532±0.170 |
3 | 0.968±0.012 | 0.552±0.198 | 0.582±0.153 | 0.547±0.169 | |
5 | 0.964±0.012 | 0.555±0.196 | 0.589±0.151 | 0.548±0.168 | |
7 | 0.940±0.011 | 0.553±0.201 | 0.601±0.151 | 0.547±0.168 | |
0.6 | 1 | 0.967±0.012 | 0.547±0.198 | 0.596±0.155 | 0.545±0.170 |
3 | 0.954±0.012 | 0.553±0.200 | 0.591±0.154 | 0.547±0.174 | |
5 | 0.940±0.011 | 0.559±0.203 | 0.592±0.159 | 0.546±0.169 | |
7 | 0.941±0.011 | 0.572±0.203 | 0.574±0.158 | 0.541±0.165 | |
0.8 | 1 | 0.967±0.011 | 0.549±0.207 | 0.593±0.154 | 0.546±0.169 |
3 | 0.940±0.011 | 0.559±0.204 | 0.596±0.155 | 0.546±0.173 | |
5 | 0.941±0.011 | 0.584±0.201 | 0.557±0.151 | 0.543±0.172 | |
7 | 0.941±0.012 | 0.623±0.198 | 0.500±0.151 | 0.503±0.168 |