Table 1 Sequence parameters

From: Quantifying coronary sinus flow and global LV perfusion at 3T

Parameter

bTFE

PC MR

TR

4 ms

5.4 ms *

TE

2 ms

3.5 ms *

α°

40°

10°

BW

940 Hz/pixel

680 Hz/pixel *

SENSE reduction

2.0

2.0

In-plane resolution

1.3 × 1.3 mm2

1.3 × 1.3 mm2*

Slice thickness

8 mm

8 mm

Number of slices

1a, 15–20b

1

Heart phases

30

21

Segmentation factor

9

10

venc

-----

56 cm/s *

Time resolution

35 ms

45 ms *

Acquisition time

10 s/slice

22 s *

  1. Table 1 summarizes the sequence parameters for the balanced TFE sequence and for the PC MR sequence. The former was used for LV-imaging and positioning of the PC MR, and the latter for flow measurements in the CS. Varying parameters are given as the average of the values used for the different scans, and marked with *.
  2. a2- 3- and 4-chamber views. bShort axis stack, covering the left ventricle and left atrium