Table 5 Performance of sequential classifiers on the MIAS database

From: Automatic detection of anomalies in screening mammograms

Wavelet basis§ Classified normal Classified suspicious Confidence level (%)
  Actually normal Actually suspicious Actually normal Actually suspicious C even (N) C even (S)
Bior 2.8 56 5 149 93 84.3 56.6
Bior 6.8 23 0 126 93 100.0 60.7
Bior 3.7 9 1 117 92 81.1 62.2
Haar 50 5 67 87 82.7 73.1
Db 8 5 3 62 84 44.3 73.9
  1. §Wavelet basis notation: Dbn where n describes the number of coefficients used in the wavelet. Db2 encodes polynomials with two coefficients, i.e. constant and linear components. Biorm.n where n describes the order for decompositiona and m is the order used for reconstruction.
  2. Suspicious images were passed to the next classifier in the chain.