Table 2 Freesurfer summary data quality measures of the initial T1-weighted volume protocols and their ranking relative to the other protocols in parentheses

From: Quantitative and qualitative assessment of structural magnetic resonance imaging data in a two-center study

   Bert A B C* D E F*
Euler No. Right −40 −396 (1) −62 (5) −66 (4) −78 (3) −94 (2) −40 (6)
  Left −58 −510 (1) −88 (2) −72 (4) −62 (5) −74 (3) −52 (6)
CNR Grey/white 2.02 1.50 (1) 2.21 (2) 2.5 (4) 2.59 (5) 2.26 (3) 2.86 (6)
  Grey/CSF 1.09 0.51 (1) 0.69 (2) 0.78 (5) 0.73 (3) 0.75 (4) 0.94 (6)
sum of scores    4 11 17 16 12 24
  1. Protocols with better summary data quality measures are given higher scores.
  2. Criteria:
  3. Euler No : the less negative the better,
  4. Grey/white CNR: the bigger the better,
  5. Grey/CSF CNR : the bigger the better,
  6. Total CNR : the bigger the better.
  7. * The MRI protocols taken forward to the next step.